Metal-enhanced fluorescence from zinc substrates can lead to spectral distortion and a wavelength dependence

dc.contributor.authorHamo, Hilla Ben
dc.contributor.authorKarolin, Jan
dc.contributor.authorMali, Buddha L.
dc.contributor.authorKushmaro, Ariel
dc.contributor.authorMarks, Robert
dc.contributor.authorGeddes, Chris
dc.date.accessioned2024-10-01T18:05:29Z
dc.date.available2024-10-01T18:05:29Z
dc.date.issued2015-02-25
dc.description.abstractMetal-enhanced fluorescence enhancement factors up to 7-fold have been observed for Basic Fuchsin (BF) in close proximity to Zinc nano particulate substrates. In addition, the emission spectra of BF close-to Zinc as compared to a control sample are heavily distorted, particularly on the red-edge, giving systematic trends in enhancement, anywhere from 3- to 7-fold. We discuss these remarkable wavelength dependent effects with regard to the mechanism of metal-enhanced fluorescence.
dc.description.urihttps://pubs.aip.org/aip/apl/article-abstract/106/8/081605/1077805/Metal-enhanced-fluorescence-from-zinc-substrates?redirectedFrom=fulltext
dc.format.extent5 pages
dc.genrejournal articles
dc.identifierdoi:10.13016/m2xh8h-sqh0
dc.identifier.citationHamo, Hilla Ben, Jan Karolin, Buddha Mali, Ariel Kushmaro, Robert Marks, and Chris D. Geddes. ‘Metal-Enhanced Fluorescence from Zinc Substrates Can Lead to Spectral Distortion and a Wavelength Dependence’. Applied Physics Letters 106, no. 8 (25 February 2015): 081605. https://doi.org/10.1063/1.4913671.
dc.identifier.urihttps://doi.org/10.1063/1.4913671
dc.identifier.urihttp://hdl.handle.net/11603/36579
dc.language.isoen_US
dc.publisherAIP
dc.relation.isAvailableAtThe University of Maryland, Baltimore County (UMBC)
dc.relation.ispartofUMBC Institute of Fluorescence (IoF)
dc.relation.ispartofUMBC Faculty Collection
dc.relation.ispartofUMBC Chemistry & Biochemistry Department
dc.relation.ispartofUMBC Student Collection
dc.rightsThis article may be downloaded for personal use only. Any other use requires prior permission of the author and AIP Publishing. This article appeared in Hamo, Hilla Ben, Jan Karolin, Buddha Mali, Ariel Kushmaro, Robert Marks, and Chris D. Geddes. ‘Metal-Enhanced Fluorescence from Zinc Substrates Can Lead to Spectral Distortion and a Wavelength Dependence’. Applied Physics Letters 106, no. 8 (25 February 2015): 081605. https://doi.org/10.1063/1.4913671. and may be found at https://pubs.aip.org/aip/apl/article/106/8/081605/1077805/Metal-enhanced-fluorescence-from-zinc-substrates.
dc.titleMetal-enhanced fluorescence from zinc substrates can lead to spectral distortion and a wavelength dependence
dc.typeText
dcterms.creatorhttps://orcid.org/0000-0002-9110-6374