Limitations of Signal Averaging of Dial Measurements Due to Temporal Correlation*
| dc.contributor.author | Menyuk, N. | |
| dc.contributor.author | Killinger, D. K. | |
| dc.contributor.author | Menyuk, Curtis | |
| dc.date.accessioned | 2025-06-17T14:45:16Z | |
| dc.date.available | 2025-06-17T14:45:16Z | |
| dc.date.issued | 1982-06-21 | |
| dc.description | International Laser Radar Conference 1982 Wisconsin United States 21–25 June 1982 | |
| dc.description.abstract | The accuracy of the remote sensing of species in the atmosphere using a differential-absorption LIDAR (DIAL) system is dependent upon the determination of the value of the "on-resonance" DIAL return compared to the "off-resonance" value. The accuracy of such measurements can generally be improved by increasing the number of measurements and taking average values. This paper describes the results of an experiment which directly measured the effect of averaging on the measurement uncertainty, where the uncertainty is defined by the standard deviation of the mean value of the returns. Our results show that the reduction of the standard deviation by signal averaging over increasing numbers of pulses is much smaller than would be anticipated for independent measurements and is due to small but long-term temporal correlation. The results are shown to be in excellent agreement with a theoretical analysis which takes the correlation of successive LIDAR returns into account. | |
| dc.description.uri | https://opg.optica.org/abstract.cfm?uri=LRC-1982-TGRDT87 | |
| dc.format.extent | 4 pages | |
| dc.genre | conference papers and proceedings | |
| dc.identifier | doi:10.13016/m2xv5b-bsyv | |
| dc.identifier.citation | Menyuk, N., D. K. Killinger, and C. R. Menyuk. “Limitations of Signal Averaging of Dial Measurements Due to Temporal Correlation*.” Eleventh International Laser Radar Conference (1982), Paper TGRDT87, June 21, 1982, TGRDT87. https://opg.optica.org/abstract.cfm?uri=LRC-1982-TGRDT87 | |
| dc.identifier.uri | http://hdl.handle.net/11603/38869 | |
| dc.language.iso | en_US | |
| dc.publisher | Optica | |
| dc.relation.isAvailableAt | The University of Maryland, Baltimore County (UMBC) | |
| dc.relation.ispartof | UMBC Faculty Collection | |
| dc.relation.ispartof | UMBC Computer Science and Electrical Engineering Department | |
| dc.rights | This item is likely protected under Title 17 of the U.S. Copyright Law. Unless on a Creative Commons license, for uses protected by Copyright Law, contact the copyright holder or the author. | |
| dc.subject | Laser systems | |
| dc.subject | Lidar | |
| dc.subject | Remote sensing | |
| dc.subject | UMBC Optical Fiber Communications Laboratory | |
| dc.subject | Energy | |
| dc.subject | Carbon dioxide lasers | |
| dc.subject | Lasers | |
| dc.title | Limitations of Signal Averaging of Dial Measurements Due to Temporal Correlation* | |
| dc.type | Text | |
| dcterms.creator | https://orcid.org/0000-0003-0269-8433 |
Files
Original bundle
1 - 1 of 1