Computer-aided diagnostic detection system of venous beading in retinal images
| dc.contributor.author | Yang, Ching-Wen | |
| dc.contributor.author | Ma, DyeJyun | |
| dc.contributor.author | Chao, ShuennChing | |
| dc.contributor.author | Wang, Chuin-Mu | |
| dc.contributor.author | Wen, Chia-Hsien | |
| dc.contributor.author | Lo, ChienShun | |
| dc.contributor.author | Chung, Pau-Choo | |
| dc.contributor.author | Chang, Chein-I | |
| dc.date.accessioned | 2024-06-11T13:30:12Z | |
| dc.date.available | 2024-06-11T13:30:12Z | |
| dc.date.issued | 2000-05-01 | |
| dc.description.abstract | The detection of venous beading in retinal images provides an early sign of diabetic retinopathy and plays an important role as a preprocessing step in diagnosing ocular diseases. We present a computer-aided diagnostic system to automatically detect venous beading of blood vessels. It comprises of two modules, referred to as the blood vessel extraction module (BVEM) and the venus beading detection module (VBDM). The former uses a bell-shaped Gaussian kernel with 12 azimuths to extract blood vessels while the latter applies a neural network-based shape cognitron to detect venous beading among the extracted blood vessels for diagnosis. Both modules are fully computerautomated. To evaluate the proposed system, 61 retinal images (32 beaded and 29 normal images) are used for performance evaluation. | |
| dc.description.uri | https://www.spiedigitallibrary.org/journals/optical-engineering/volume-39/issue-5/0000/Computer-aided-diagnostic-detection-system-of-venous-beading-in-retinal/10.1117/1.602487.full | |
| dc.format.extent | 11 pages | |
| dc.genre | journal articles | |
| dc.identifier | doi:10.13016/m2gvkc-apqn | |
| dc.identifier.citation | Yang, Ching-Wen, DyeJyun Ma, ShuennChing Chao, Chuin-Mu Wang, Chia-Hsien Wen, ChienShun Lo, Pau-Choo Chung, and Chein-I. Chang. “Computer-Aided Diagnostic Detection System of Venous Beading in Retinal Images.” Optical Engineering 39, no. 5 (May 2000): 1293–1303. https://doi.org/10.1117/1.602487. | |
| dc.identifier.uri | https://doi.org/10.1117/1.602487 | |
| dc.identifier.uri | http://hdl.handle.net/11603/34577 | |
| dc.language.iso | en_US | |
| dc.publisher | SPIE | |
| dc.relation.isAvailableAt | The University of Maryland, Baltimore County (UMBC) | |
| dc.relation.ispartof | UMBC Faculty Collection | |
| dc.relation.ispartof | UMBC Computer Science and Electrical Engineering Department | |
| dc.rights | ©2000 Society of Photo-Optical Instrumentation Engineers (SPIE). One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited. | |
| dc.title | Computer-aided diagnostic detection system of venous beading in retinal images | |
| dc.type | Text | |
| dcterms.creator | https://orcid.org/0000-0002-5450-4891 |