Assessment of the performance of ECC-ozonesondes under quasi-flight conditions in the environmental simulation chamber: Insights from the Juelich Ozone Sonde Intercomparison Experiment (JOSIE)
| dc.contributor.author | Smit, Herman G. J. | |
| dc.contributor.author | Straeter, Wolfgang | |
| dc.contributor.author | Johnson, Bryan J. | |
| dc.contributor.author | Oltmans, Samuel J. | |
| dc.contributor.author | Davies, Jonathan | |
| dc.contributor.author | Tarasick, David W. | |
| dc.contributor.author | Hoegger, Bruno | |
| dc.contributor.author | Stubi, Rene | |
| dc.contributor.author | Schmidlin, F. J. | |
| dc.contributor.author | Northam, T. | |
| dc.contributor.author | Thompson, Anne M. | |
| dc.contributor.author | Witte, Jacquelyn C. | |
| dc.contributor.author | Boyd, Ian | |
| dc.contributor.author | Posny, Françoise | |
| dc.date.accessioned | 2024-07-26T16:34:45Z | |
| dc.date.available | 2024-07-26T16:34:45Z | |
| dc.date.issued | 2007-10-11 | |
| dc.description.abstract | Since 1996, quality assurance experiments of electrochemical concentration cell (ECC) ozonesondes of two different model types (SPC-6A and ENSCI-Z) have been conducted in the environmental simulation facility at the Research Centre Juelich within the framework of the Juelich Ozone Sonde Intercomparison Experiment (JOSIE). The experiments have shown that the performance characteristics of the two ECC-sonde types can be significantly different, even when operated under the same conditions. Particularly above 20 km the ENSCI-Z sonde tends to measure 5–10% more ozone than the SPC-6A sonde. Below 20 km the differences are 5% or less, but appear to show some differences with year of manufacture. There is a significant difference in the ozone readings when sondes of the same type are operated with different cathode sensing solutions. Testing the most commonly used sensing solutions showed that for each ECC-manufacturer type the use of 1.0% KI and full buffer gives 5% larger ozone values compared with the use of 0.5% KI and half buffer, and as much as 10% larger values compared with 2.0% KI and no buffer. For ozone sounding stations performing long term measurements this means that changing the sensing solution type or ECC-sonde type can easily introduce a change of ±5% or more in their records, affecting determination of ozone trends. Standardization of operating procedures for ECC-sondes yields a precision better than ±(3–5)% and an accuracy of about ±(5–10)% up to 30 km altitude. | |
| dc.description.sponsorship | We want to thank Volker Mohnen (Univer-sity of Albany), John Miller, Michael Proffitt and Len Barrie (WMO/AREP) for their personal engagement, contributions and arranging financialsupport for JOSIE. Many thanks to Dieter Kley (Research Centre Juelich)for his encouragement in establishing JOSIE as a unique facility forozonesonde quality assurance. Also many thanks to Manfred Helten forassistance in conducting the JOSIE campaigns. Special thanks to GilbertLevrat from Aerological Station Payerne, Switzerland, Dave Ross fromNASA/GSFC-Wallops Flight Facility, USA, Jim Kerr from EnvironmentCanada, Canada, and Greg Bodeker from National Institute of Water andAtmospheric Research, New Zealand for their assistance at the JOSIE-campaigns. Karin Thomas of KT-Consulting many thanks for assistance inthe data analysis. Further, we are grateful to all other people involved in theJOSIE-missions for their encouraging support and fruitful discussions.JOSIE was sponsored by WMO/GAW, QA/SAC-Germany and FZJ/HGF.We are grateful to three anonymous referees for many helpful commentsand suggestions. | |
| dc.description.uri | https://agupubs.onlinelibrary.wiley.com/doi/full/10.1029/2006JD007308 | |
| dc.format.extent | 18 pages | |
| dc.genre | journal articles | |
| dc.identifier | doi:10.13016/m2copw-mv6t | |
| dc.identifier.citation | Smit, Herman G. J., Wolfgang Straeter, Bryan J. Johnson, Samuel J. Oltmans, Jonathan Davies, David W. Tarasick, Bruno Hoegger, et al. “Assessment of the Performance of ECC-Ozonesondes under Quasi-Flight Conditions in the Environmental Simulation Chamber: Insights from the Juelich Ozone Sonde Intercomparison Experiment (JOSIE).” Journal of Geophysical Research: Atmospheres 112, no. D19 (2007). https://doi.org/10.1029/2006JD007308. | |
| dc.identifier.uri | https://doi.org/10.1029/2006JD007308 | |
| dc.identifier.uri | http://hdl.handle.net/11603/35017 | |
| dc.language.iso | en_US | |
| dc.publisher | AGU | |
| dc.relation.isAvailableAt | The University of Maryland, Baltimore County (UMBC) | |
| dc.relation.ispartof | UMBC GESTAR II | |
| dc.rights | This work was written as part of one of the author's official duties as an Employee of the United States Government and is therefore a work of the United States Government. In accordance with 17 U.S.C. 105, no copyright protection is available for such works under U.S. Law. | |
| dc.rights | Public Domain | |
| dc.rights.uri | https://creativecommons.org/publicdomain/mark/1.0/ | |
| dc.subject | Ozone | |
| dc.subject | ozonesonde | |
| dc.subject | ECC | |
| dc.title | Assessment of the performance of ECC-ozonesondes under quasi-flight conditions in the environmental simulation chamber: Insights from the Juelich Ozone Sonde Intercomparison Experiment (JOSIE) | |
| dc.type | Text | |
| dcterms.creator | https://orcid.org/0000-0002-7829-0920 |