Microgrid Protection through Adaptive Overcurrent Relay Coordination

dc.contributor.authorBawayan, Haneen
dc.contributor.authorYounis, Mohamed
dc.date.accessioned2021-12-09T18:34:33Z
dc.date.available2021-12-09T18:34:33Z
dc.date.issued2021-11-05
dc.description.abstractThe inclusion of distributed energy resources (DER) in Microgrids (MGs) comes at the expense of increased changes in current direction and magnitude. In the autonomous mode of MG operation, the penetration of synchronous distributed generators (DGs) induces lower short circuit current than when the MG operates in the grid-connected mode. Such behavior impacts the overcurrent relays and makes the protection coordination difficult. This paper introduces a novel adaptive protection system that includes two phases to handle the influence of fault current variations and enable the MG to sustain its operation. The first phase optimizes the power flow by minimizing the generators’ active power loss while considering tolerable disturbances. For intolerable cases, the second phase opts to contain the effect of disturbance within a specific area, whose boundary is determined through correlation between primary/backup relay pairs. A directional overcurrent relay (DOCR) coordination optimization is formulated as a nonlinear program for minimizing the operating time of the relays within the contained area. Validation is carried out through the simulation of the IEEE 9, IEEE 14, and IEEE 15 bus systems as an autonomous MG. The simulation results demonstrate the effectiveness of our proposed protection system and its superiority to a competing approach in the literature.en_US
dc.description.sponsorshipThis research received no external funding.en_US
dc.description.urihttps://www.mdpi.com/2673-4826/2/4/31en_US
dc.format.extent30 pagesen_US
dc.genrejournal articlesen_US
dc.identifierdoi:10.13016/m20m6i-iibo
dc.identifier.citationBawayan, Haneen; Younis, Mohamed; Microgrid Protection through Adaptive Overcurrent Relay Coordination; Electricity, 2(4), 524-553, 5 November, 2021; https://doi.org/10.3390/electricity2040031en_US
dc.identifier.urihttps://doi.org/10.3390/electricity2040031
dc.identifier.urihttp://hdl.handle.net/11603/23566
dc.language.isoen_USen_US
dc.publisherMDPIen_US
dc.relation.isAvailableAtThe University of Maryland, Baltimore County (UMBC)
dc.relation.ispartofUMBC Computer Science and Electrical Engineering Department Collection
dc.relation.ispartofUMBC Faculty Collection
dc.rightsThis item is likely protected under Title 17 of the U.S. Copyright Law. Unless on a Creative Commons license, for uses protected by Copyright Law, contact the copyright holder or the author.en_US
dc.rightsAttribution 4.0 International (CC BY 4.0)*
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/*
dc.titleMicrogrid Protection through Adaptive Overcurrent Relay Coordinationen_US
dc.typeTexten_US
dcterms.creatorhttps://orcid.org/0000-0002-6663-8053en_US
dcterms.creatorhttps://orcid.org/0000-0003-3865-9217en_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
electricity-02-00031.pdf
Size:
2.08 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.56 KB
Format:
Item-specific license agreed upon to submission
Description: