Demonstration of Athena X-IFU Compatible 40-Row Time-Division-Multiplexed Readout

dc.contributor.authorDurkin, Malcolm
dc.contributor.authorAdams, Joseph S.
dc.contributor.authorBandler, Simon R.
dc.contributor.authorChervenak, James A.
dc.contributor.authorMiniussi, Antoine
dc.contributor.authorSakai, Kazuhiro
dc.contributor.authorSmith, Stephen J.
dc.contributor.authorWakeham, Nicholas
dc.contributor.authoret al
dc.date.accessioned2022-01-18T15:49:48Z
dc.date.available2022-01-18T15:49:48Z
dc.date.issued2019-03-19
dc.descriptionMalcolm Durkin , Joseph S. Adams, Simon R. Bandler, James A. Chervenak, Saptarshi Chaudhuri, Carl S. Dawson, Edward V. Denison, William B. Doriese , Shannon M. Duff, Fred M. Finkbeiner , Connor T. FitzGerald, Joseph W. Fowler, Johnathon D. Gard, Gene C. Hilton, Kent D. Irwin, Young Il Joe, Richard L. Kelley, Caroline A. Kilbourne , Antoine Miniussi, Kelsey M. Morgan , Galen C. O’Neil, Christine G. Pappas, Frederick S. Porter, Carl D. Reintsema, David A. Rudman, Kazuhiro Sakai, Stephen J. Smith, Robert W. Stevens, Daniel S. Swetz, Paul Szypryt, Joel N. Ullom, Leila R. Vale, Nicholas Wakeham , Joel C. Weber, and Betty A. Youngen_US
dc.description.abstractTime-division multiplexing (TDM) is the backup readout technology for the X-ray Integral Field Unit (X-IFU), a 3168-pixel X-ray transition-edge sensor (TES) array that will provide imaging spectroscopy for european space agency’s Athena satellite mission. X-IFU design studies are considering readout with a multiplexing factor of up to 40. We present data showing 40-row TDM readout (32 TES rows + 8 repeats of the last row) of TESs that are of the same type as those being planned for X-IFU, using measurement and analysis parameters within the ranges specified for X-IFU. Single-column TDM measurements have best-fit energy resolution of (1.91 ± 0.01) eV for the Al Kα complex (1.5 keV), (2.10 ± 0.02) eV for Ti Kα (4.5 keV), (2.23 ± 0.02) eV for Mn Kα (5.9 keV), (2.40 ± 0.02) eV for Co Kα (6.9 keV), and (3.44 ± 0.04) eV for Br Kα (11.9 keV). Three-column measurements have best-fit resolution of (2.03 ± 0.01) eV for Ti Kα and (2.40 ± 0.01) eV for Co Kα. The degradation due to the multiplexed readout ranges from 0.1 eV at the lower end of the energy range to 0.5 eV at the higher end. The demonstrated performance meets X-IFU’s energy-resolution and energy-range requirements. True 40-row TDM readout, without repeated rows, of kilopixel scale arrays of X-IFU-like TESs is now under development.en_US
dc.description.urihttps://ieeexplore.ieee.org/document/8671478en_US
dc.format.extent5 pagesen_US
dc.genrejournal articlesen_US
dc.identifierdoi:10.13016/m2isti-4ihk
dc.identifier.citationM. Durkin et al., "Demonstration of Athena X-IFU Compatible 40-Row Time-Division-Multiplexed Readout," in IEEE Transactions on Applied Superconductivity, vol. 29, no. 5, pp. 1-5, Aug. 2019, Art no. 2101005, doi: 10.1109/TASC.2019.2904472.en_US
dc.identifier.urihttps://doi.org/10.1109/TASC.2019.2904472
dc.identifier.urihttp://hdl.handle.net/11603/24013
dc.language.isoen_USen_US
dc.publisherIEEEen_US
dc.relation.isAvailableAtThe University of Maryland, Baltimore County (UMBC)
dc.relation.ispartofUMBC Center for Space Sciences and Technology
dc.relation.ispartofUMBC Physics Department
dc.relation.ispartofUMBC Faculty Collection
dc.rightsThis work was written as part of one of the author's official duties as an Employee of the United States Government and is therefore a work of the United States Government. In accordance with 17 U.S.C. 105, no copyright protection is available for such works under U.S. Law.en_US
dc.rightsPublic Domain Mark 1.0*
dc.rights.urihttp://creativecommons.org/publicdomain/mark/1.0/*
dc.titleDemonstration of Athena X-IFU Compatible 40-Row Time-Division-Multiplexed Readouten_US
dc.typeTexten_US
dcterms.creatorhttps://orcid.org/0000-0003-0622-5174en_US
dcterms.creatorhttps://orcid.org/0000-0003-4096-4675en_US
dcterms.creatorhttps://orcid.org/0000-0002-9247-3010en_US
dcterms.creatorhttps://orcid.org/0000-0001-8397-9338en_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Demonstration_of_Athena_X-IFU_Compatible_40-Row_Time-Division-Multiplexed_Readout.pdf
Size:
1.92 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.56 KB
Format:
Item-specific license agreed upon to submission
Description: