Wireless bipotentiostat circuit for glucose and H2O2 interrogation
dc.contributor.advisor | Slaughter, Gymama | |
dc.contributor.author | Annamalai, Priyanka | |
dc.contributor.department | Computer Science and Electrical Engineering | |
dc.contributor.program | Engineering, Computer | |
dc.date.accessioned | 2021-01-29T18:13:47Z | |
dc.date.available | 2021-01-29T18:13:47Z | |
dc.date.issued | 2019-01-01 | |
dc.description.abstract | Here we present a cost-effective point-of-use wireless platform for the electrochemical detection of low concentrations of glucose and hydrogen peroxide (H2O2) simultaneously. The electrochemical system utilizes a dual sensor integrated with a portable bipotentiostat. The bipotentiostat hardware implements a basic design that reduces the cost of construction and increases the affordability of the instrument, while providing similar functionality to the more expensive bench-top potentiostats. The bipotentiostat utilizes inexpensive components, common Ag/AgCl reference and platinum counter electrodes, two working electrodes, and it is designed to detect currents within the range of 20 uA to 7 mA. Additionally, the bipotentiostat is integrated with wireless module ESP8266 that interfaces with a smartphone to enable real-time monitoring and visualization of the analyte concentration levels. The results show that the self-designed bipotentiostat is capable of performing chronoamperometry and demonstrate an electrochemical detection system that is a portable alternative system for laboratory and point-of-use testing. | |
dc.format | application:pdf | |
dc.genre | theses | |
dc.identifier | doi:10.13016/m2y38r-r9cu | |
dc.identifier.other | 12040 | |
dc.identifier.uri | http://hdl.handle.net/11603/20905 | |
dc.language | en | |
dc.relation.isAvailableAt | The University of Maryland, Baltimore County (UMBC) | |
dc.relation.ispartof | UMBC Computer Science and Electrical Engineering Department Collection | |
dc.relation.ispartof | UMBC Theses and Dissertations Collection | |
dc.relation.ispartof | UMBC Graduate School Collection | |
dc.relation.ispartof | UMBC Student Collection | |
dc.source | Original File Name: Annamalai_umbc_0434M_12040.pdf | |
dc.title | Wireless bipotentiostat circuit for glucose and H2O2 interrogation | |
dc.type | Text | |
dcterms.accessRights | Distribution Rights granted to UMBC by the author. | |
dcterms.accessRights | Access limited to the UMBC community. Item may possibly be obtained via Interlibrary Loan thorugh a local library, pending author/copyright holder's permission. | |
dcterms.accessRights | This item is likely protected under Title 17 of the U.S. Copyright Law. Unless on a Creative Commons license, for uses protected by Copyright Law, contact the copyright holder or the author. |