Validation of a CT-based motion model with in-situ fluoroscopy for lung surface deformation estimation

dc.contributor.authorRanjbar, Maida
dc.contributor.authorSabouri, Pouya
dc.contributor.authorMossahebi, Sina
dc.contributor.authorSawant, Amit
dc.contributor.authorMohindra, Pranshu
dc.contributor.authorLasio, Giovanni
dc.contributor.authorTopoleski, L D Timme
dc.date.accessioned2020-12-10T18:34:56Z
dc.date.available2020-12-10T18:34:56Z
dc.date.issued2020-11-18
dc.description.abstractMany surrogate-based motion models (SMMs), proposed to guide motion management in radiotherapy, are constructed by correlating motion of an external surrogate and internal anatomy during CT-simulation. Changes in this correlation define model break down. We validate a methodology that incorporates fluoroscopic images (FL) acquired during treatment for SMM construction and update. Under a prospective IRB, 4DCT scans, VisionRT surfaces, and orthogonal FLs were collected from five lung cancer patients. VisionRT surfaces and two FL time-series were acquired pre- and post-treatment. A simulated annealing optimization scheme was used to estimate optimal lung deformations by maximizing the mutual information between digitally reconstructed radiographs (DRRs) of the SMM-estimated 3D images and FLs. Our SMM used partial-least-regression and was trained using the optimal deformations and VisionRT surfaces from the first breathing-cycle. SMM performance was evaluated using the mutual information score between reference FLs and the corresponding SMM or phase-assigned 4DCT DRRs. The Hausdorff distance for contoured landmarks was used to evaluate target position estimation error. For four out of five patients, two principal components approximated lung surface deformations with submillimeter accuracy. Analysis of the mutual information score between more than 4,000 pairs of FL and DRR demonstrated that our model led to more similarity between the FL and DRR images compared to 4DCT and DRR images from a model based on an a priori correlation model. Our SMM consistently displayed lower mean and 95th percentile Hausdorff distances. For one patient, 95th percentile Hausdorff distance was reduced by 11mm. Patient-averaged reductions in mean and 95th percentile Hausdorff distances were 3.6mm and 7mm for right-lung, and 3.1mm and 4mm for left-lung targets. FL data were used to evaluate model performance and investigate the feasibility of model update. Despite variability in breathing, use of post-treatment FL preserved model fidelity and consistently outperformed 4DCT for position estimation.en_US
dc.description.sponsorshipThis work was supported in part by the University of Maryland, Baltimore County dissertation fellowship award. Our methodology was demonstrated on patient data collected as a collaborative effort by the faculty and staff at the University of Maryland Medical Center and University of Maryland Upper Chesapeake Health Center. These data collection efforts were partially supported by NIH R01 CA-169102. One author (AS) also wishes to acknowledge the support of Varian Medical Systems and VisionRT in connection with the data collection efforts. The authors wish to express sincere gratitude to Nancy Knight, PhD, and Ms. Kaysee Baker for supporting the collegial academic environment in which this research was completed.en_US
dc.description.urihttps://iopscience.iop.org/article/10.1088/1361-6560/abcbcf/metaen_US
dc.format.extent38 pagesen_US
dc.genrejournal articles postprintsen_US
dc.identifierdoi:10.13016/m2comg-xror
dc.identifier.citationMaida Ranjbar et al., Validation of a CT-based motion model with in-situ fluoroscopy for lung surface deformation estimation, Physics in Medicine & Biology, DOI: https://doi.org/10.1088/1361-6560/abcbcfen_US
dc.identifier.urihttps://doi.org/10.1088/1361-6560/abcbcf
dc.identifier.urihttp://hdl.handle.net/11603/20228
dc.language.isoen_USen_US
dc.publisherIOPen_US
dc.relation.isAvailableAtThe University of Maryland, Baltimore County (UMBC)
dc.relation.ispartofUMBC Mechanical Engineering Department Collection
dc.relation.ispartofUMBC Faculty Collection
dc.relation.ispartofUMBC Student Collection
dc.rightsThis item is likely protected under Title 17 of the U.S. Copyright Law. Unless on a Creative Commons license, for uses protected by Copyright Law, contact the copyright holder or the author.
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 International*
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.titleValidation of a CT-based motion model with in-situ fluoroscopy for lung surface deformation estimationen_US
dc.typeTexten_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Ranjbar+et+al_2020_Phys._Med._Biol._10.1088_1361-6560_abcbcf.pdf
Size:
2.5 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.56 KB
Format:
Item-specific license agreed upon to submission
Description: