Application of the Rd/w framework to assess Donnan dialysis performance

dc.contributor.authorChen, Hui
dc.contributor.authorSouizi, Sahar
dc.contributor.authorStewart, Kaylyn
dc.contributor.authorBlaney, Lee
dc.date.accessioned2025-04-23T20:31:02Z
dc.date.available2025-04-23T20:31:02Z
dc.date.issued2023-12-01
dc.description.abstractDonnan dialysis exploits electrochemical potential gradients across ion-exchange membranes to separate ions between feed and draw solutions. This technique has been applied for treatment and recovery of chemicals in water and wastewater. Previous studies have arbitrarily selected the draw solution chemistry, making it difficult to fairly compare experimental outcomes. A universal framework is needed to standardize design and interpretation of Donnan dialysis systems. We calculated the Rd/w parameter, which is related to the draw ion concentrations in the feed and draw solutions at Donnan equilibrium, for previous studies. Rd/w values were used to determine theoretical recoveries and compare them to experimental outcomes. Of the literature data, 57% matched the theoretical recovery, 37% underperformed due to operating time constraints or transport limitations, and 6% outperformed Donnan equilibrium due to use of integrated processes. Ultimately, this work highlights the benefits of the Rd/w framework for standardizing interpretation of Donnan dialysis systems.
dc.description.sponsorshipWe acknowledge funding from the United States Department of Agriculture (project #MD.W-2019-06552) to support the literature review and conceptualization of this article.
dc.description.urihttps://www.sciencedirect.com/science/article/pii/S2211339823000710
dc.format.extent23 pages
dc.genrejournal articles
dc.genrepostprints
dc.identifierdoi:10.13016/m2bow5-5kiv
dc.identifier.citationChen, Hui, Sahar Souizi, Kaylyn Stewart, and Lee Blaney. "Application of the Rd/w Framework to Assess Donnan Dialysis Performance" Current Opinion in Chemical Engineering 42 (1 December 2023): 100967. https://doi.org/10.1016/j.coche.2023.100967.
dc.identifier.urihttps://doi.org/10.1016/j.coche.2023.100967
dc.identifier.urihttp://hdl.handle.net/11603/38015
dc.language.isoen_US
dc.publisherElsevier
dc.relation.isAvailableAtThe University of Maryland, Baltimore County (UMBC)
dc.relation.ispartofUMBC Chemical, Biochemical & Environmental Engineering Department
dc.relation.ispartofUMBC Faculty Collection
dc.relation.ispartofUMBC Student Collection
dc.relation.ispartofUMBC Chemistry & Biochemistry Department
dc.rightsCreative Commons Attribution Non-Commercial No Derivatives License
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.en
dc.titleApplication of the Rd/w framework to assess Donnan dialysis performance
dc.typeText
dcterms.creatorhttps://orcid.org/0000-0002-2735-1068
dcterms.creatorhttps://orcid.org/0009-0004-3820-1382
dcterms.creatorhttps://orcid.org/0000-0003-1904-5252
dcterms.creatorhttps://orcid.org/0000-0003-0181-1326

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1s2.0S2211339823000710am.pdf
Size:
382.51 KB
Format:
Adobe Portable Document Format